Plaintext Password Disclosure via VBScript Sensor Error Message in Paessler PRTG Network Monitor
PRTG Network Monitor before version 26.2.120.1449 ships a demo EXE/Script sensor that multiplies two integer parameters using cscript.exe. If a non-numeric value is passed instead, cscript.exe raises a 'Type mismatch' runtime error that includes the offending parameter value in plaintext. PRTG provides a documented placeholder variable, %windowspassword, which resolves to the configured Windows/domain password used by PRTG and can be passed as a sensor parameter. Any PRTG user who is not restricted to read-only access and is permitted to create sensors (the default for non-read-only users) can pass %windowspassword as an argument to the demo VBScript sensor, triggering the type-mismatch error and causing PRTG to display the plaintext password in the sensor's error output.
CVE-2026-4638
Primary source · Revision 1
Imported from structured advisory data. Source references identify upstream records or fields; verify affected versions and your deployed configuration.
Security context
Source reference: cve:CVE-2026-4638
PRTG Network Monitor
Source reference: /containers/cna/affected/0/product
- Affected versions
- Not stated in this record
- Fixed versions
- Not stated in this record
- Prerequisites
- Not stated in this record
Structured affected-version data
Original package identities and version rules from this source.
[
{
"vendor": "Paessler GmbH",
"product": "PRTG Network Monitor",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "26.2.120.1449",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
]- Related CVEs