{"schema_version":"1","data":[{"id":27102,"advisory_id":"9ac9d9c1-5d4c-41f8-81f8-e6fa4c1e3a65","revision":1,"source_id":"core-cve","source_url":"https://www.cve.org/CVERecord?id=CVE-2025-59375","source_published_at":"2025-09-15T00:00:00+00:00","published_at":"2026-10-25T07:20:07.642617+00:00","extraction_method":"structured","technologies":["core-cve","libexpat"],"cve_ids":["CVE-2025-59375"],"event_types":["advisory"],"payload":{"kind":"advisory","title":"CVE-2025-59375","summary":"libexpat in Expat before 2.7.2 allows attackers to trigger large dynamic memory allocations via a small document that is submitted for parsing.","evidence":"cve:CVE-2025-59375","products":[{"name":{"value":"libexpat","evidence":"/containers/cna/affected/0/product"},"prerequisites":[],"fixed_versions":[],"affected_versions":[]}],"severity":"high","structured":{"id":"CVE-2025-59375","aliases":["CVE-2025-59375"],"metrics":[{"cvssV3_1":{"version":"3.1","baseScore":7.5,"baseSeverity":"HIGH","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:H/RL:T/RC:C"}}],"affected":[{"vendor":"libexpat project","product":"libexpat","versions":[{"status":"affected","version":"0","lessThan":"2.7.2","versionType":"semver"}],"defaultStatus":"unaffected"}],"modified":"2026-10-15T01:09:25.199Z","provider":"cve","references":["https://github.com/libexpat/libexpat/issues/1018","https://github.com/libexpat/libexpat/pull/1034","https://github.com/libexpat/libexpat/blob/676a4c531ec768732fac215da9730b5f50fbd2bf/expat/Changes#L45-L74","https://issues.oss-fuzz.com/issues/439133977","https://github.com/libexpat/libexpat/blob/R_2_7_2/expat/Changes"],"provider_metadata":{"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2025-59375","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2025-09-15T20:22:58.509715Z"}}}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2025-09-15T20:23:08.737Z"}},{"title":"CVE Program Container","references":[{"url":"http://www.openwall.com/lists/oss-security/2025/09/16/2"},{"url":"http://www.openwall.com/lists/oss-security/2026/05/01/5"}],"providerMetadata":{"orgId":"af854a3a-2127-422b-91ae-364da2661108","shortName":"CVE","dateUpdated":"2026-05-01T14:25:12.055Z"}},{"affected":[{"vendor":"Siemens","product":"RUGGEDCOM RST2428P","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XC-300/XR-300/XC-400/XR-500WG/XR-500 family","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XCH328","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XCM324","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XCM328","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XCM332","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRH334 (24 V DC, 8xFO, CC)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 12xFO)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (230 V AC, 8xFO)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 12xFO)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (24 V DC, 8xFO)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 12xFO)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230 V AC, 8xFO)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)","versions":[{"status":"affected","version":"0","lessThan":"V3.3","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.5","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.5","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.5","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.5","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"},{"vendor":"Siemens","product":"SIPLUS S7-1500 CPU 1518-4 PN/DP MFP","versions":[{"status":"affected","version":"V3.1.5","lessThan":"*","versionType":"custom"}],"defaultStatus":"unknown"}],"x_adpType":"supplier","references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-082556.html"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-089022.html"}],"providerMetadata":{"orgId":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e","shortName":"siemens-SADP","dateUpdated":"2026-10-15T01:09:25.199Z"}}],"cna":{"orgId":"8254265b-2729-46b6-b9e3-3dfca2d5bfca","shortName":"mitre","dateUpdated":"2025-09-17T13:21:47.961Z"}}},"related_cves":[{"value":"CVE-2025-59375","evidence":"/cveMetadata/cveId"}],"security_relevant":true,"severity_evidence":"/containers/cna/metrics"},"priority":{"reasons":["publisher_severity"],"severity":"high","linked_cves":[],"fix_available":false,"known_exploited":false,"publisher_severity":"high"},"context_update":false}],"next_after":27102,"next_before":27102}