{"schema_version":"1","data":[{"id":3794,"advisory_id":"fcbd54a0-980f-4cfe-b714-bb1c650f4cf7","revision":1,"source_id":"core-cve","source_url":"https://www.cve.org/CVERecord?id=CVE-2026-8066","source_published_at":"2026-09-29T09:24:05.83+00:00","published_at":"2026-10-24T21:40:49.320233+00:00","extraction_method":"structured","technologies":["core-cve","rtu500-series-cmu-firmware"],"cve_ids":["CVE-2026-8066"],"event_types":["advisory"],"payload":{"kind":"advisory","title":"CVE-2026-8066","summary":"A directory traversal vulnerability in the file upload functionality of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to write or overwrite arbitrary files on the device file system. Depending on the files affected, successful exploitation could result in unauthorized modification of device data or disruption of the device’s intended operation.","evidence":"cve:CVE-2026-8066","products":[{"name":{"value":"RTU500 series CMU firmware","evidence":"/containers/cna/affected/0/product"},"prerequisites":[],"fixed_versions":[],"affected_versions":[]}],"severity":"critical","structured":{"id":"CVE-2026-8066","aliases":["CVE-2026-8066"],"metrics":[{"format":"CVSS","cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":9.1,"attackVector":"NETWORK","baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"NONE"},"scenarios":[{"lang":"en","value":"GENERAL"}]}],"affected":[{"vendor":"Hitachi Energy","product":"RTU500 series CMU firmware","versions":[{"status":"affected","version":"9.0","lessThan":"12.0","versionType":"custom"}],"defaultStatus":"unaffected"}],"modified":"2026-09-29T15:52:33.807Z","provider":"cve","references":["https://publisher.hitachienergy.com/preview?DocumentID=8DBD000251&LanguageCode=en&DocumentPartId=&Action=Launch"],"provider_metadata":{"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2026-8066","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2026-09-29T15:52:09.514722Z"}}}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-09-29T15:52:33.807Z"}}],"cna":{"orgId":"e383dce4-0c27-4495-91c4-0db157728d17","shortName":"Hitachi Energy","dateUpdated":"2026-09-29T12:50:58.301Z"}}},"related_cves":[{"value":"CVE-2026-8066","evidence":"/cveMetadata/cveId"}],"security_relevant":true,"severity_evidence":"/containers/cna/metrics"},"priority":{"reasons":["publisher_severity"],"severity":"critical","linked_cves":[],"fix_available":false,"known_exploited":false,"publisher_severity":"critical"},"context_update":false},{"id":3793,"advisory_id":"3315dde7-6b0c-47b6-9df6-cef0f1d8c1bb","revision":1,"source_id":"core-cve","source_url":"https://www.cve.org/CVERecord?id=CVE-2026-8065","source_published_at":"2026-09-29T09:20:07.276+00:00","published_at":"2026-10-24T21:40:48.753778+00:00","extraction_method":"structured","technologies":["core-cve","rtu500-series-cmu-firmware"],"cve_ids":["CVE-2026-8065"],"event_types":["advisory"],"payload":{"kind":"advisory","title":"CVE-2026-8065","summary":"An authentication bypass vulnerability in the firmware update endpoint of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to upload arbitrary firmware through a crafted POST request. Successful exploitation could allow the attacker to modify device functionality or compromise the integrity or availability of the device.","evidence":"cve:CVE-2026-8065","products":[{"name":{"value":"RTU500 series CMU firmware","evidence":"/containers/cna/affected/0/product"},"prerequisites":[],"fixed_versions":[],"affected_versions":[]}],"severity":"critical","structured":{"id":"CVE-2026-8065","aliases":["CVE-2026-8065"],"metrics":[{"format":"CVSS","cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":9.1,"attackVector":"NETWORK","baseSeverity":"CRITICAL","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H","integrityImpact":"HIGH","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"NONE","confidentialityImpact":"NONE"},"scenarios":[{"lang":"en","value":"GENERAL"}]}],"affected":[{"vendor":"Hitachi Energy","product":"RTU500 series CMU firmware","versions":[{"status":"affected","version":"9.0","lessThan":"12.0","versionType":"custom"}],"defaultStatus":"unaffected"}],"modified":"2026-09-29T15:54:11.550Z","provider":"cve","references":["https://publisher.hitachienergy.com/preview?DocumentID=8DBD000251&LanguageCode=en&DocumentPartId=&Action=Launch"],"provider_metadata":{"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2026-8065","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"yes"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2026-09-29T15:53:38.135052Z"}}}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-09-29T15:54:11.550Z"}}],"cna":{"orgId":"e383dce4-0c27-4495-91c4-0db157728d17","shortName":"Hitachi Energy","dateUpdated":"2026-09-29T12:50:06.355Z"}}},"related_cves":[{"value":"CVE-2026-8065","evidence":"/cveMetadata/cveId"}],"security_relevant":true,"severity_evidence":"/containers/cna/metrics"},"priority":{"reasons":["publisher_severity"],"severity":"critical","linked_cves":[],"fix_available":false,"known_exploited":false,"publisher_severity":"critical"},"context_update":false},{"id":3489,"advisory_id":"49c1f460-efef-410d-8956-27adbf54fb1b","revision":1,"source_id":"core-cve","source_url":"https://www.cve.org/CVERecord?id=CVE-2026-8067","source_published_at":"2026-09-29T09:33:52.627+00:00","published_at":"2026-10-24T21:36:06.058104+00:00","extraction_method":"structured","technologies":["core-cve","rtu500-series-cmu-firmware"],"cve_ids":["CVE-2026-8067"],"event_types":["advisory"],"payload":{"kind":"advisory","title":"CVE-2026-8067","summary":"An improper authorization vulnerability in the end-of-life versions of RTU500’s web application allows an authenticated user to trigger the RTU500 to reboot through the reset endpoint. Successful exploitation could cause temporary device unavailability and disruption of its intended operation.","evidence":"cve:CVE-2026-8067","products":[{"name":{"value":"RTU500 series CMU firmware","evidence":"/containers/cna/affected/0/product"},"prerequisites":[],"fixed_versions":[],"affected_versions":[]}],"severity":"medium","structured":{"id":"CVE-2026-8067","aliases":["CVE-2026-8067"],"metrics":[{"format":"CVSS","cvssV3_1":{"scope":"UNCHANGED","version":"3.1","baseScore":6.5,"attackVector":"NETWORK","baseSeverity":"MEDIUM","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","integrityImpact":"NONE","userInteraction":"NONE","attackComplexity":"LOW","availabilityImpact":"HIGH","privilegesRequired":"LOW","confidentialityImpact":"NONE"},"scenarios":[{"lang":"en","value":"GENERAL"}]}],"affected":[{"vendor":"Hitachi Energy","product":"RTU500 series CMU firmware","versions":[{"status":"affected","version":"9.0","lessThan":"12.0","versionType":"custom"}],"defaultStatus":"unaffected"}],"modified":"2026-09-29T15:05:10.350Z","provider":"cve","references":["https://publisher.hitachienergy.com/preview?DocumentID=8DBD000251&LanguageCode=en&DocumentPartId=&Action=Launch"],"provider_metadata":{"adp":[{"title":"CISA ADP Vulnrichment","metrics":[{"other":{"type":"ssvc","content":{"id":"CVE-2026-8067","role":"CISA Coordinator","options":[{"Exploitation":"none"},{"Automatable":"no"},{"Technical Impact":"partial"}],"version":"2.0.3","timestamp":"2026-09-29T15:04:54.700468Z"}}}],"providerMetadata":{"orgId":"134c704f-9b21-4f2e-91b3-4a467353bcc0","shortName":"CISA-ADP","dateUpdated":"2026-09-29T15:05:10.350Z"}}],"cna":{"orgId":"e383dce4-0c27-4495-91c4-0db157728d17","shortName":"Hitachi Energy","dateUpdated":"2026-09-29T12:51:51.369Z"}}},"related_cves":[{"value":"CVE-2026-8067","evidence":"/cveMetadata/cveId"}],"security_relevant":true,"severity_evidence":"/containers/cna/metrics"},"priority":{"reasons":[],"severity":"medium","linked_cves":[],"fix_available":false,"known_exploited":false,"publisher_severity":"medium"},"context_update":false}],"next_after":3794,"next_before":3489}