High
TRO600 Series Firmware — security advisory
TRO600 contains an arbitrary file read vulnerability. An unauthenticated attacker can exploit this vulnerability to read or download arbitrary files on the affected device, including sensitive configuration files and password data, resulting in the disclosure of sensitive information.
- Products
- TRO600 Series Firmware
- Affected versions
- Not specified
- Fixed versions
- Not specified
- CVEs
- CVE-2026-106087
- Confirmed fixed CVEs
- Not specified
- Updated in this feed
- 31 Oct 2026, 13:45 UTC · Revision 1
Source evidence
TRO600 contains an arbitrary file read vulnerability. An unauthenticated attacker can exploit this vulnerability to read or download arbitrary files on the affected device, including sensitive configuration files and password data, resulting in the disclosure of sensitive information.
cve:CVE-2026-106087
TRO600 Series Firmware
Fixed versions: Not specified
Complete source record
{
"id": "a384f66c1126ecfb14ca2a4ddf142d49dc28bd2f78695e786985f94e9371736e",
"url": "https://www.cve.org/CVERecord?id=CVE-2026-106087",
"method": "structured",
"payload": {
"kind": "advisory",
"title": "CVE-2026-106087",
"summary": "TRO600 contains an arbitrary file read vulnerability. An unauthenticated attacker can exploit this vulnerability to read or download arbitrary files on the affected device, including sensitive configuration files and password data, resulting in the disclosure of sensitive information.",
"evidence": "cve:CVE-2026-106087",
"products": [
{
"name": {
"value": "TRO600 Series Firmware",
"evidence": "/containers/cna/affected/0/product"
},
"prerequisites": [],
"fixed_versions": [],
"affected_versions": []
}
],
"severity": "high",
"structured": {
"id": "CVE-2026-106087",
"aliases": [
"CVE-2026-106087"
],
"metrics": [
{
"format": "CVSS",
"cvssV4_0": {
"Safety": "NOT_DEFINED",
"version": "4.0",
"Recovery": "NOT_DEFINED",
"baseScore": 8.7,
"Automatable": "NOT_DEFINED",
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"exploitMaturity": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"affected": [
{
"vendor": "Hitachi Energy",
"product": "TRO600 Series Firmware",
"versions": [
{
"status": "affected",
"version": "9.0.0.0",
"versionType": "custom",
"lessThanOrEqual": "9.1.1.0"
}
],
"defaultStatus": "unaffected"
}
],
"modified": "2026-10-27T11:56:54.738Z",
"provider": "cve",
"references": [
"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000224&LanguageCode=en&DocumentPartId=&Action=Launch"
],
"provider_metadata": {
"cna": {
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy",
"dateUpdated": "2026-10-27T11:56:54.738Z"
}
}
},
"related_cves": [
{
"value": "CVE-2026-106087",
"evidence": "/cveMetadata/cveId"
}
],
"security_relevant": true,
"severity_evidence": "/containers/cna/metrics"
},
"source_id": "core-cve",
"document_id": 391947,
"published_at": "2026-10-27T11:56:54.738+00:00"
}